Rogers RO4360G2 PCB Parameters: One Dk, Three Materials

RO4360G2 exists for one reason: it is the only 6.15 Dk laminate in the RO4000 platform, and it processes like FR-4. That single sentence explains every parameter on its data sheet, and it also explains the mistake that most descriptions of this material make — they treat “Dk 6.15” as a performance claim rather than a geometry claim. At 6.15 the line width and the guided wavelength are fixed; what is still open is the loss per wavelength, the drift with temperature and the process route. Three Rogers materials sit at the same 6.15 and each answers those three questions differently. This article reads the RO4360G2 data sheet row by row, converts each row into the decision it actually governs, and puts the other two 6.15 materials beside it.

Rogers RO4360G2 PCB Parameters manufactured by XCE PCB for RF and microwave applications

What the Part Number Names, and What It Does Not

RO4360G2 is a glass-reinforced, ceramic-filled hydrocarbon thermoset from the RO4000 platform, specified at Dk 6.15 ±0.15 with a design value of 6.4 and a dissipation factor of 0.0038 at 10 GHz. It is not PTFE, it is not a filled epoxy, and the “G2” is a revision of the same 6.15 Dk idea rather than a new resin system. The nearest neighbour in the catalogue is RO4350B at Dk 3.48, and the two share the press chemistry, the drill behaviour and the plating route.

That last point is the commercial case and the technical constraint at the same time. Because the resin is a thermoset with woven glass, the material cures in a 190–200 °C press cycle and bonds to ordinary FR-4 prepreg, so a mixed stack-up is a single lamination rather than a sequential build. Because it is a thermoset, it also inherits the hydrocarbon family’s temperature coefficient of Dk — and at 6.15 Dk with a −131 ppm/°C slope, that inheritance is expensive in a way it is not at 3.48.

The description that circulates online gets three things wrong before it reaches the first number: it calls the construction “ceramic fillers, glass fibres and epoxy resin”, it gives the X-axis CTE as 17 ppm/°C, and it treats the material as a general-purpose high-frequency grade for satellite and automotive work. The construction is a hydrocarbon thermoset, not an epoxy; the CTE set is 13/14/28; and the two applications that most need a 6.15 Dk — a patch antenna element and a feed network — are exactly the two that react differently to this material’s temperature drift. Each of those is treated below with the number that makes it matter.

The Data Sheet, Row by Row

These are the published values, with the condition attached, because on this family the condition is half the specification. The right-hand column is the part most descriptions leave out: what the row actually decides.

PropertyValueConditionWhat it decides
Dk, process6.15 ±0.1510 GHz / 23 °C, clamped striplineLine width and guided wavelength; ±0.15 is ±2.4 % in Dk and ±1.2 % in impedance
Dk, design6.408–40 GHz, average of lotsThe number a model should use; 4.1 % above the process value
Df0.003810 GHz / 23 °CLoss per wavelength; equal to RO4350B for practical purposes
TCDk−131 ppm/°C−50 to +150 °CPhase drift: 1.6 % Dk across 125 K, about 0.8 % in frequency
CTE X / Y / Z13 / 14 / 28−55 to +288 °CRegistration against copper at 17, and plated-barrel strain through Z
Tg>280 °CTMANo softening inside any reflow profile; Td >407 °C adds margin
Thermal conductivity0.75 W/m·K50 °C, ASTM D54703.4 K·cm²/W through 0.254 mm: 34 K rise at 10 W/cm²
Peel strength0.91 N/mm (5.2 lb/in)1 oz ED foilHalf of what PTFE grades reach; sets the minimum line width at fine pitch
Water absorption0.08 %D48/50Four times 5880, eight times 6010.2LM; matters in a humid enclosure
Density2.16 g/cm³—Heavier than 4350B at 1.79: +21 % substrate mass
Dielectric strength784 V/milIPC-TM-650 2.5.6.2Isolation spacing at altitude, not at 50 Ω
UL 94V-0—Unlike 4003C, which carries no rating at all

Two rows are worth a second reading. The design Dk of 6.4 sits 4.1 % above the process value of 6.15, which is the largest gap in the RO4000 platform, and section 3 shows what happens to a model that ignores it. The peel strength of 0.91 N/mm is the lowest number on the sheet, lower than 4350B’s 1.05 and far below the 1.6–2.1 N/mm of the ceramic-filled PTFE grades; it is adequate, it is just not the place to look for margin.

Two Dk Numbers, and the 47 Degrees Between Them

A Dk quoted at one condition and used at another is the most common way a 6.15 Dk design misses. The process value 6.15 comes from a clamped stripline at 10 GHz; the design value 6.4 is an average of several lots measured as a circuit, which is what a microstrip or a patch actually is. Designing on 6.15 and building on 6.4 does not produce a 4 % error in impedance — it produces a 1.9 % error in electrical length, and electrical length is what a matching network is made of.

QuantityOn Dk 6.15On Dk 6.40Error if you design on 6.15
Effective Dk, 50 Ω microstrip4.414.58+3.8 %
Guided wavelength at 10 GHz14.28 mm14.02 mm1.8 % short
50 Ω width on 0.254 mm core0.361 mm0.361 mmWidth is set by Dk; the model would use the wrong one
Phase over 100 mm at 10 GHz——7 wavelengths × 0.018 = 47°
Phase over 100 mm at 28 GHz——19.6 wavelengths × 0.018 = 132°

Forty-seven degrees at 10 GHz is not a rounding error; it is the difference between a Wilkinson divider that isolates and one that leaks. The practical rule is that both numbers go on the drawing: the process value with its tolerance for the material call-out, and the design value for the model. Where a design is tuned on a coupon the gap disappears in measurement, which is why the failure shows up on second-source lots and not on the first build.

The tolerance adds a second, smaller term. ±0.15 on 6.15 is ±2.4 % in Dk, which is ±1.2 % in impedance and in electrical length — a quarter of the design/process gap, but it never goes away, and on a narrow line it arrives together with the etch tolerance. The budget arithmetic for that combination is set out in ten critical parameters for high-frequency PCBs.

What Dk 6.15 Does to Geometry

The reason to accept 0.0038 rather than the 0.0020 of a PTFE grade is size, and size is arithmetic. At 50 Ω the width-to-height ratio falls from 2.21 on 3.48 Dk to 1.42 on 6.15, the guided wavelength falls from 17.8 mm to 14.3 mm at 10 GHz, and a resonant element therefore shrinks by about 20 % in each dimension and 36 % in area.

LaminateDkW/h for 50 ΩWidth on 0.254 mmGuided λ at 10 GHzPatch area vs 3.48
RO30033.002.540.645 mm19.3 mm1.18×
RO4350B3.482.210.561 mm17.8 mm1.00×
RO4360G26.151.420.361 mm14.3 mm0.64×
RO301010.20.850.216 mm11.0 mm0.39×

Read the width column with the peel strength in mind. A 0.361 mm line at 1 oz is comfortable; the same design taken to 10.2 Dk lands at 0.216 mm, where the etch tolerance of ±25 µm becomes an 11.6 % width error and therefore roughly a 6 % impedance error. That is the reason 6.15 is a popular compromise between the two: it buys a third of the area without entering the geometry where the etch process starts to set the impedance. The 10.2 end of the same trade is quantified in the RO3010 parameter set.

There is a second-order consequence that only appears in manufacture: at 0.36 mm the line is wider than the dielectric is thick by a factor of 1.4, so the field is mostly in the substrate and the microstrip behaves close to a homogeneous line. That is helpful for repeatability, and it also means the solder mask on top matters less than it does on a 0.65 mm line on 3.00 Dk, where a third of the field is in air and in the coating.

Loss Per Inch, Loss Per Wavelength, and Why Both Are True

Here is the number that contradicts the marketing. On a per-inch basis RO4360G2 is lossier than RO4350B: 0.245 dB/inch of dielectric loss against 0.180, because the dielectric term scales with √Dk and Df while Df is essentially identical. On a per-wavelength basis the two are within 3 %, because a wavelength on 6.15 is 20 % shorter and the same physical length contains more wavelengths.

LaminateDkDfDielectric dB/inch at 10 GHzdB per guided λdB per 100 mm
RO30066.150.00200.1290.0730.51
RT/duroid 60066.150.00270.1740.0980.69
RO4360G26.150.00380.2450.1380.96
RO4350B3.480.00370.1800.1260.71
FR-44.200.0201.0660.704.20

Both columns are honest and they answer different questions. Per 100 mm, RO4360G2 costs 0.96 dB of dielectric loss against 0.71 for 4350B, so a 100 mm feed run is 35 % worse; but the same 100 mm holds the electrical length that would have needed 125 mm on 4350B, so a like-for-like comparison in wavelengths is 0.138 against 0.126. Which column applies depends on whether the board is constrained by physical length or by electrical length. A patch array is constrained by neither — it is constrained by element spacing, and there the 20 % shrink is worth more than 0.012 dB per wavelength.

The table also sets the ceiling. At 10 GHz the dielectric term is 0.245 dB/inch, and the conductor term for 1 oz copper on a 0.361 mm line is comparable; at 28 GHz the dielectric term rises to 0.69 dB/inch and the conductor term rises more slowly, so the material dominates. This is the opposite of the low-Df PTFE case, where copper dominates from 10 GHz upward. Which is why the finish and the foil matter less here than the laminate, and less than they do on a 5880 board — the trade is set out in PCB surface treatment processes.

The Same Dk, Three Materials

Dk 6.15 appears three times in the Rogers catalogue, and the three entries differ in almost nothing that affects geometry and in almost everything that affects the rest of the design. This is the comparison the part number cannot make for you.

 RO4360G2RT/duroid 6006RO3006
Resin systemHydrocarbon ceramic, glass-reinforced, thermosetPTFE with ceramic fillerPTFE with ceramic filler, no woven glass
Dk / design Dk6.15 ±0.15 / 6.46.15 ±0.15 / 6.456.15 ±0.15 / 6.15
Df at 10 GHz0.00380.00270.0020
TCDk−131 ppm/°C−410 ppm/°C≈ −3 ppm/°C
CTE X / Y / Z13 / 14 / 2847 / 34 / 11717 / 17 / 24
Thermal conductivity0.75 W/m·K0.49 W/m·K0.79 W/m·K
Water absorption0.08 %0.05 %0.02 %
Press cycle190–200 °C, bonds to FR-4 prepregPTFE bonding route, 260–300 °C or low-flow prepregPTFE bonding route
Plated holesStandard desmearSodium-naphthalene or plasmaSodium-naphthalene or plasma
Best reason to choose itOne-shot hybrid with FR-4; FR-4 tooling; V-0Balanced loss and CTE, PTFE stabilityLowest loss at 6.15 and near-zero TCDk

The pattern is clean. Switching from 4360G2 to 3006 halves the dielectric loss and removes the temperature drift almost entirely, and in exchange the board stops being an FR-4 job: the press becomes a PTFE press, the hole activation becomes a sodium-naphthalene or plasma step, and the hybrid with FR-4 becomes sequential rather than one-shot. That cost is real and it is not quoted as a material price. The layer-order and bonding consequences of it are set out in high-frequency PCB stack-up design.

One row is deliberately missing from the table: peel strength. RO4360G2 is quoted at 0.91 N/mm with 1 oz ED foil, while the ceramic-filled PTFE grades in this Dk bracket publish 1.6 N/mm on 6002 and 2.1 N/mm on 6010.2LM. On a 0.36 mm line that difference is margin rather than a limit, but it is the reason fine-line designs on this laminate keep the copper at 1/2 oz and lean on plating rather than on foil thickness.

RT/duroid 6006 sits between the two and is the least understood of the three. It has twice the loss of 3006 and a TCDk of −410 ppm/°C, the worst in the family, and a Z-axis CTE of 117. What it offers is a tighter Dk distribution than 3006 in some builds and availability in thicknesses 3006 does not stock. For a new design at 6.15 Dk with a phase requirement, 3006 is the technically correct answer; 4360G2 is the answer when the board has to leave an FR-4 line.

TCDk −131: the High-Dk Tax, in Degrees

The temperature coefficient of Dk is the parameter that separates the three 6.15 materials most sharply, and it is the one most often omitted from a comparison written from the marketing sheet. −131 ppm/°C over 125 K is a 1.64 % change in Dk, and since frequency scales as 1/√Dk the resonant frequency moves 0.82 %.

BandShift over 25–150 °CShift over 25–85 °CWhat it means
2.4 GHz20 MHz9.4 MHzInside a 100 MHz channel; tolerable
10 GHz82 MHz39 MHzA filter passband is typically 200–500 MHz wide
28 GHz230 MHz110 MHzA 28 GHz channel is 400 MHz; half the margin is gone
77 GHz631 MHz303 MHzWider than the 1 GHz radar band allows for a phase-critical array

Two conclusions follow, and they point in opposite directions. A radiating element tolerates this drift: a patch whose resonant frequency moves 0.8 % still radiates, with a small mismatch at band edges, and the 36 % area saving is usually worth it. A feed network or a filter does not: 47–132° of phase error across the operating temperature range puts the array out of coherence, and no amount of Dk tolerance on the purchase order fixes it. So the honest rule for 4360G2 is antennas yes, phase-critical networks only with compensation — and the compensation options are a material with a near-zero TCDk such as 3006 at −3 ppm/°C, or a tunable element in the chain.

This is also where the “ideal for satellite and automotive” wording in the circulating description fails. A 77 GHz automotive radar front end built on 4360G2 works for the antenna, and the loss budget at 0.0038 Df is workable for short runs; the phase drift is the constraint, not the loss. For space, the material’s data sheet publishes no ASTM E595 outgassing figures, and a payload specification that requires TML and CVCM cannot be met by a grade that does not quote them — the PTFE grades that do are compared in the RT/duroid 5880 parameter set.

Z-Axis 28: Better Than the Platform, Not Close to Copper

28 ppm/°C in Z is a genuine improvement on 4350B’s 32 and on 4003C’s 46, and it is still 1.6 times copper at 17. Across a 1.6 mm board and a 215 K excursion that is 9.6 µm of expansion against 11.0 for 4350B, 15.8 for 4003C and 82 for 5880 — so the plated barrel sees a differential that is manageably small rather than negligible.

LaminateZ CTEExpansion, 1.6 mm × 215 KAspect ratio ceiling
RO4360G2289.6 µm8:1 with 25 µm plating
RO4350B3211.0 µm8:1
RO4003C4615.8 µm8:1
RT/duroid 600611740.2 µm6:1
RT/duroid 588023781.5 µm6:1

The practical consequence is that a 2.4 mm, 12-layer board on 4360G2 with 0.25 mm vias is a normal build at roughly 10:1, which is where ordinary high-Tg FR-4 practice already lives; the same stack on 5880 would need 6:1 and would not close. The rules that do not relax are the ones about plating: 25 µm minimum copper in the barrel, elongation of 20 % or better, and a drill programme that does not tear the glass — the same discipline as 4350B, because it is the same resin family.

Thermal: 0.75 W/m·K Is an Improvement, Not a Solution

0.75 W/m·K is the highest thermal conductivity in the RO4000 platform and about 2.5 times a standard FR-4, and it is still a fifth of what a thermally conductive grade reaches. The number that matters is thermal resistance through the dielectric, which is thickness divided by conductivity.

Materialk, W/m·KR through 0.254 mmRise at 10 W/cm²Rise at 30 W/cm²
RO4360G20.753.4 K·cm²/W34 K101 K
RO4350B0.693.7 K·cm²/W37 K110 K
RO4003C0.713.6 K·cm²/W36 K107 K
RO6035HTC1.441.8 K·cm²/W18 K53 K
RT/duroid 58800.2012.7 K·cm²/W127 K381 K

A base-station power amplifier at 10 W/cm² therefore sees 34 K through the laminate, which is a real improvement over FR-4’s 85 K and nothing like a solution at 30 W/cm². The rest of the path — thermal vias, the copper balance underneath, the heat sink interface — still has to be designed, and it is the same vias-in-pad discipline as on any other RF board. Where the thermal requirement is the primary one rather than a by-product, the ceramic-filled high-conductivity grade is the answer, and it is measured in the RT/duroid 6035HTC analysis.

Thickness, Copper and the Configurations That Exist

The original description gives the dielectric thickness as “0.2 to 1.5 mm”, which is the range but not the catalogue. RO4360G2 is stocked in six core thicknesses, with non-standard values on a 0.004 in pitch, and it is cladded with 1/2 oz or 1 oz electrodeposited copper only.

ConfigurationDetailDesign consequence
Standard cores0.008 / 0.016 / 0.020 / 0.024 / 0.032 / 0.060 in = 0.203 / 0.406 / 0.508 / 0.610 / 0.813 / 1.524 mmSix widths per Dk; a 50 Ω line runs 0.288–2.17 mm across them
Non-standard0.008–0.060 in in 0.004 in (0.102 mm) incrementsMost impedance targets can be hit without a bond ply; check lead time
Copper1/2 oz and 1 oz EDNo rolled or HVLP option from stock: foil roughness is not a lever here
BondingRO4400 prepreg, or a lower-Dk RO4000 laminate as the paired layerOne-shot hybrid with FR-4 is possible; the bond ply still adds to h
PanelStandard Rogers panel sizes, cut to 600×1200 mm in-houseLarge arrays are panel-limited, not press-limited

Two of these rows decide more projects than the Dk does. The absence of a rolled-copper option means the conductor loss cannot be bought down the way it can on a 3003 board, so on this material the loss budget is set once by Df and thickness. And because bonding adds to the dielectric height, a stack that uses RO4400 to join two cores has an h that is not the core thickness on the drawing — the error is 0.10 mm of bond ply turning a 50 Ω line into 61 Ω if it is left out of the model.

Processing: FR-4 Rules With Two Deltas

The processing claim on this material is accurate: it runs on FR-4 equipment. The two deltas are worth knowing before the first panel is released.

Press. The cure window is 190–200 °C, above the 170–190 °C of a standard FR-4 cycle, so a hybrid stack needs a profile that satisfies both and a press programme that does not exceed the FR-4’s Tg-driven expansion before the RO4400 flows. Drill. The woven glass is the same class as FR-4, so point geometry and hit count are ordinary; the difference is that the resin is filled, which dulls tools faster and shows up as barrel roughness rather than as smear. Desmear is permanganate, as on FR-4 — unlike a PTFE grade, which needs sodium-naphthalene or plasma and cannot be activated by permanganate at all.

StepRO4360G2PTFE grade at the same Dk
Lamination190–200 °C, one-shot hybrid with FR-4260–300 °C fusion or 180–190 °C low-flow; sequential only
DesmearPermanganateSodium-naphthalene or plasma; permanganate does not activate PTFE
DrillingFR-4 parameters; filled resin dulls tools fasterLower spindle load, sharp tools, risk of cold flow at the hole
Solder maskStandard; Dk of the mask is a second dielectricAdhesion promoter required; mask Dk still counts
Surface finishENIG, OSP, immersion tin/silver — all qualifiedHASL at 250–260 °C is a thermal shock on a soft substrate

The finish choice is the one place where the two families converge, because the nickel in ENIG is a conductor at 10 GHz regardless of what is underneath: 3–6 µm of nickel has 2.04 times the sheet resistance of copper at that frequency, and the current does not care whether the laminate is thermoset or PTFE. On a 0.0038 Df material that nickel term is a smaller share of the total than on a 0.0009 material, which is the one genuine advantage of a lossier laminate.

Six Statements From the Circulating Description

The description this article replaces is 766 words long and contains six statements that do not survive the data sheet. Each is paired below with the published value and the decision it distorts.

StatementData sheetWhy it matters
“Dissipation factor typically 0.003”0.0038A 27 % understatement: the design that was supposed to clear the budget by 20 % clears it by nothing
“CTE about 17 ppm/°C along X”13 X, 14 Y, 28 Z17 is copper’s number, not this material’s; the Z value is the one that governs plated barrels
“Ceramic fillers, glass fibres and epoxy resin”Glass-reinforced hydrocarbon ceramic, thermosetNo epoxy: the press window at 190–200 °C and the permanganate desmear both follow from the chemistry
“Dielectric thickness 0.2 to 1.5 mm”Six standard cores, 0.203–1.524 mm, 0.102 mm pitch non-standardA tolerance-free range invites a thickness that is not stocked
“Operating temperature −55 to +125 °C”No such rating; Tg >280, Td >407, CTE measured −55 to +288125 °C is a component convention, not a laminate limit; it hides the −131 ppm/°C drift
“Ideal for satellite communication and automotive radar”Rogers lists base-station PAs, small cells, patch antennas, ground radarNo E595 outgassing data for space; 77 GHz phase networks fail on drift, not on loss

None of these is a defect in the material. Every one of them is a defect in the copy, and each has a specific failure mode attached: the Df error eats the link budget, the CTE error misplaces the plated-hole calculation on the wrong axis, the chemistry error sets the wrong press programme, the thickness error orders a non-stock core, the temperature error hides the one parameter that decides whether an array holds phase, and the application error sends the material into a qualification it cannot pass. The family context for all six is in the RO4000 platform overview, and the value case for the Dk itself is in what Dk 6.15 buys and what it costs.

What Goes on the Drawing

Because three materials share this Dk and only one of them runs on an FR-4 line, an ambiguous call-out is the most expensive mistake available. Seven lines close it: the grade with the full name RO4360G2; Dk as 6.15 ±0.15 process and 6.40 design, with which one the model used; Df 0.0038 at 10 GHz with the test method; core thickness in millimetres with tolerance quoted as core, not finished dielectric; copper weight and foil type, accepting that only ED is stocked; the bond ply by name, since RO4400 changes h; and the finish, with an explicit note that nickel-bearing finishes add conductor loss that this laminate cannot recover.

XCE PCB builds these boards on the FR-4 route they were designed for: 2 to 72 layers, impedance held to ±10 % on coupons cut from the panel centre and edge, panels up to 600×1200 mm, samples in as fast as 24 hours, inspected to IPC-A-600G and IPC-6015. Send the stack-up for a quote, or WhatsApp +86 180 3341 4657.

Conclusion

RO4360G2 is a 6.15 Dk hydrocarbon ceramic thermoset with 0.0038 loss, 13/14/28 CTE, 0.75 W/m·K, V-0 and an FR-4 press window. It buys 36 % less board area than RO4350B and 20 % shorter guided wavelength, and it charges 2.7 % more loss per wavelength, a 1.6 % Dk drift across 125 K and a peel strength of 0.91 N/mm.

The comparison that decides most projects is not against 4350B but against the other two 6.15 materials. RO3006 halves the dielectric loss and removes the drift, at the price of a PTFE process; RT/duroid 6006 sits between them with a TCDk of −410. If the board must leave an FR-4 line, 4360G2 is the only one of the three that can; if it must hold phase over temperature, it is the only one of the three that cannot.

What the material will not do is what the circulating description promises: it is not 0.003 loss, not 17 ppm CTE in all axes, not an epoxy, not rated to 125 °C and not a space or 77 GHz front-end grade by default. Built on the published rows, it is a very good answer to a narrow question — how to shrink an antenna on a process you already own — and the same question at the 10.2 Dk end is answered in the RO3010 against RO3003 comparison.

Frequently Asked Questions

What is the dielectric constant of RO4360G2?
6.15 ±0.15 as a process value at 10 GHz measured by clamped stripline, and 6.40 as a design value averaged over lots from 8 to 40 GHz. The gap is 4.1 %, the largest in the RO4000 platform, and designing on the process value while the circuit behaves as the design value costs about 1.9 % of electrical length — 47° over 100 mm at 10 GHz.
Is RO4360G2 PTFE?
No. It is a glass-reinforced, ceramic-filled hydrocarbon thermoset, and that is why it cures at 190–200 °C, bonds to FR-4 prepreg in a single press cycle and can be desmeared with permanganate. PTFE grades at the same 6.15 Dk — RT/duroid 6006 and RO3006 — need a 260–300 °C bonding route and sodium-naphthalene or plasma hole activation.
What is the dissipation factor of RO4360G2?
0.0038 at 10 GHz, against 0.0037 for RO4350B. On a per-inch basis that makes it the lossier of the two, 0.245 dB/inch of dielectric loss versus 0.180, because the dielectric term scales with √Dk. Per guided wavelength the two are within 3 %, because a wavelength at 6.15 is 20 % shorter.
Which is better at 6.15 Dk: RO4360G2, RO3006 or RT/duroid 6006?
It depends on the constraint. RO3006 has the lowest loss at 0.0020 and a TCDk of about −3 ppm/°C, so it wins any phase-critical design — at the cost of a PTFE process. RT/duroid 6006 is 0.0027 with a −410 ppm/°C drift. RO4360G2 at 0.0038 is the only one that processes like FR-4, so it wins when the board has to be built on an existing FR-4 line.
Can RO4360G2 be used at 77 GHz?
For the antenna, yes: the 20 % wavelength reduction shrinks the array and 0.0038 Df is workable over short runs. For a phase-critical feed network, no — a −131 ppm/°C TCDk moves the resonant frequency 0.8 % across 125 K, which is 631 MHz at 77 GHz and wider than the radar band allows.
How thick is RO4360G2 available?
Six standard cores: 0.008, 0.016, 0.020, 0.024, 0.032 and 0.060 inch (0.203 to 1.524 mm), with non-standard thicknesses from 0.008 to 0.060 inch in 0.004 inch (0.102 mm) increments. Copper is 1/2 oz or 1 oz electrodeposited only — there is no rolled or HVLP foil option from stock, so conductor loss cannot be bought down on this grade.
Does RO4360G2 have a UL 94 rating?
Yes, V-0, and it is lead-free process compatible with Tg above 280 °C by TMA and Td above 407 °C. That combination is one reason it is chosen over RO4003C, which carries no UL 94 rating at all — a distinction that decides compliance even when the electrical difference is negligible.
RF & Microwave PCB Fabrication

RO4360G2 Boards Built With FR-4 Discipline

Send us your Gerber files and requirements for a manufacturability review and a tailored quotation.

2–72 layers ±10% impedance tolerance Manufacturing since 2009