RO4003C is one of the most misquoted laminates in the industry — the same handful of parameters shows up wrong across vendor pages, including UL 94 ratings the material does not carry. This guide goes through the datasheet row by row, states what each value means in production, and corrects the common errors.

Parameters, Applications, and Production Guidelines for Rogers 4003C PCB

The Parameter Sheet, Checked Against the Datasheet

ParameterRogers datasheet valueCommonly misquoted as
Dk, process @ 10 GHz3.38 ± 0.05“3.55 ± 0.05” — design value with the wrong tolerance attached
Dk, design3.55used as the measured Dk
Df @ 10 GHz0.0027 (0.0021 @ 2.5 GHz)“below 0.002”
TCDk, −50 to +150 °C+40 ppm/°Ccredited to 4350B instead
CTE X / Y / Z11 / 14 / 46 ppm/°C“13 in X and Y”
Thermal conductivity0.71 W/(m·K)—
Tg / Td> 280 °C (TMA) / 425 °C (TGA)“300 °C thermal weight loss”
Copper peel, 1 oz ED1.05 N/mm (6.0 lb/in)—
Water absorption0.06%—
UL 94 ratingNone — non-brominated“UL 94 V-0” — this one is widespread and dangerous
Standard cores0.203 – 1.524 mm (8 – 60 mil)thicknesses borrowed from 4350B’s table

Two structural notes behind the table. First, the resin system is a thermoset hydrocarbon/ceramic composite reinforced with woven glass (1080 and 1674 fabric styles) — not thermoplastic, not PTFE. Second, RO4003C sits in the RO4000 series next to RO4350B; the full 4350B vs 4003C decision analysis covers how these numbers compare across the family.

Process Dk vs Design Dk — the Pair That Causes Re-Spins

The single most expensive parameter error on this material is feeding the field solver with 3.38. That is the process value, measured for material comparison and incoming inspection. Impedance work uses design Dk 3.55. The 0.17 gap is not noise: a 50 Ω microstrip on 0.508 mm core comes out about 3% narrower than it should, and the finished impedance lands roughly 1.5 Ω high — visible on every TDR plot and expensive to correct post-etch.

The direction of the correction matters too: design Dk is higher, so traces get wider, not narrower. Engineers who split the difference land between the two errors. Rogers publishes the design value precisely so this ambiguity does not exist — use 3.55, verify with a TDR coupon on the production panel, and treat the coupon, not the calculation, as the acceptance record.

What the Thermal Rows Mean in Production

TCDk +40 ppm/°C bounds frequency drift, not board expansion: across a −40 to +85 °C service swing, Dk moves about 0.5%, so a 10 GHz resonant structure shifts roughly 24 MHz. For outdoor and automotive hardware this is the number that justifies skipping temperature compensation.

CTE 11/14 in-plane tracks copper (17 ppm/°C) closely enough that lateral stress on fine-pitch assemblies is low. The Z-axis 46 ppm/°C is the number to respect in stack-up design: on a 1.6 mm board through a 200 K excursion, the laminate grows about 8 microns more than a 32 ppm/°C material would — acceptable on two to eight layers, cumulative on thick multilayer with many reflow cycles. That row is a real reason RO4350B exists; its Z-CTE is 32.

Tg > 280 °C and Td 425 °C together mean the laminate shrugs off lead-free reflow, multiple assembly passes and rework. Thermal conductivity 0.71 W/(m·K) is about twice FR-4 — helpful for spreading, not a substitute for thermal vias under hot components.

The UL 94 Row: Why the Misquote Is Dangerous

Vendor pages regularly list RO4003C as UL 94 V-0. It is not. The formulation is deliberately non-brominated — that is part of how Rogers keeps Df at 0.0027, because brominated flame retardants add polar groups that raise dipole loss. The trade is structural: in this family, V-0 (RO4350B) and lowest loss (RO4003C) never appear in the same laminate.

The practical failure mode is a compliance engineer discovering at certification that the bare board has no flammability rating. At that point the material changes, the stack-up changes, impedances shift by 2–3%, and the design re-enters layout. Check this row before the first quote, not after the first audit.

Production Guidelines That Follow From the Datasheet

Drilling. The ceramic filler that stabilizes Dk also abrades carbide faster than FR-4 resin. Standard carbide bits are correct — no diamond coating needed — but hit-count limits should be tightened, entry and backing boards used, and feed/speed tuned for clean hole walls rather than maximum throughput. Coolant is not part of PCB drilling; hole quality comes from chip load and tool wear management.

Desmear and PTH. Standard permanganate desmear and electroless copper. No sodium-naphthalene or plasma activation — the absence of that whole step is the material’s core economic advantage over PTFE laminates.

Lamination. Follow the bondply or prepreg supplier’s cure curve; for all-RO4003C multilayers the matched Rogers 2929 bondply is the reliable interface, and standard FR-4 prepregs (1080, 2116) work for hybrid builds. Bake laminates before lamination — 0.06% water absorption is low but not zero.

Etching and surface finish. The 1.05 N/mm peel gives clean etch definition. All standard finishes apply: ENIG, immersion silver, immersion tin, HASL, OSP. Above roughly 20 GHz, favor immersion silver or OSP on long lines to keep the ENIG nickel layer out of the RF path.

Assembly. Standard lead-free reflow profiles — the 425 °C Td and >280 °C Tg carry ample margin. Cleanroom-class assembly and special low-temperature solders are not required by this material.

Testing and Quality Control

For controlled-impedance RF builds on RO4003C, our acceptance sequence is: TDR coupon on the production panel (not a calculation report), VNA sweep on representative structures when the design is loss-critical, cross-sections on plated through-holes from first articles, and thermal cycling for boards specified to harsh environments. Parameters alone do not verify a build — but every parameter above tells you which test is likely to fail first if the process drifted: hole-wall quality traces back to drilling, delamination to lamination and moisture, impedance to the Dk you put in the solver.

Applications, Briefly

The parameter set above maps onto: base station PAs, filters and feed networks; 77 GHz automotive radar; VSAT and LNB front ends; RFID/IoT reader antennas; and general couplers, dividers and LNA stages. Where each application exploits which parameter — and the full fabrication flow — is covered in the complete RO4003C applications and fabrication guide; the commercial pitch is in the advantages overview.

How XCE PCB Builds It

XCE PCB builds RO4003C for 2 to 72 layers, impedance controlled to ±10% and TDR-verified on the production panel, panels up to 600 × 1200 mm, hybrid FR-4 stack-ups routine, samples in as fast as 24 hours when laminate is in stock. Send the stack-up and frequency band and we will flag any parameter conflict — including the UL 94 question — before quoting.

Frequently Asked Questions

What is the dielectric constant of Rogers RO4003C?
Two values: process Dk 3.38 ± 0.05 at 10 GHz (the measured material value) and design Dk 3.55 (the value for impedance modeling). Use 3.55 in your field solver — building with 3.38 yields traces about 3% narrow and impedances about 1.5 Ω high.
Is Rogers 4003C UL 94 V-0 rated?
No. RO4003C is non-brominated and carries no UL 94 rating — a point many vendor pages get wrong. RO4350B is the RO4000 family member rated V-0. The brominated chemistry that earns V-0 is also why 4350B's Df is higher: the two properties are structurally exclusive in this family.
What are the CTE values of RO4003C?
X 11, Y 14, Z 46 ppm/°C over −55 to +288 °C. In-plane values track copper closely; the Z-axis 46 is moderate — acceptable up to mid-count multilayer, but a reason to consider RO4350B (Z 32) for thick boards with many reflow cycles.
Is RO4003C thermoplastic or thermoset?
Thermoset. It is a ceramic-filled hydrocarbon resin system reinforced with woven glass (1080 and 1674 fabric styles), cured permanently during lamination. It is not PTFE and not thermoplastic — which is why it drills, desmears and plates on standard FR-4 equipment.
What thicknesses does RO4003C come in?
Standard cores run 0.203 to 1.524 mm (8 to 60 mil), with copper cladding of ½ oz, 1 oz and 2 oz ED foil. Thinner dielectrics — down to 0.101 mm — are only available in the family as RO4350B cores, where the 4 mil Dk is 3.36, not 3.48.
Does XCE PCB verify RO4003C impedance in production?
Yes. Every controlled-impedance build is verified with TDR coupons on the production panel, 2 to 72 layers, ±10% impedance control, panels up to 600 × 1200 mm, samples in as fast as 24 hours when laminate is in stock.
RF & Microwave PCB Fabrication

Need RO4003C Parameters Turned Into a Build?

Send us your Gerber files and requirements for a manufacturability review and a tailored quotation.

2–72 layers ±10% impedance tolerance Manufacturing since 2009