An f4b sheets datasheet is four lines of electrical data, a thickness ladder, a sheet size table and a mechanical row — and almost every mistake in specifying F4B comes from reading one of those lines without its qualifier. This page walks the document field by field: what each number means, what range is normal for the F4BM ladder, and which values should make you ask for the original document. It is the reading guide, not the catalog — the full model table is a separate page.
1. The Whole Document in Four Lines
Strip the marketing from a laminate datasheet and four lines carry the engineering: Dk with its tolerance, Df with the frequency it was measured at, thickness with its tolerance, and copper type with its weight. Everything else — sheet size, peel strength, solder endurance, warpage — is about whether the material can be built with, not whether it will work.
| Field | What it decides | Normal for F4BM |
|---|---|---|
| Dk ± tolerance | Line width at a given impedance | 2.17–3.00 at ±0.04 to ±0.06 |
| Df @ test frequency | Dielectric loss per inch | 0.0010–0.0018 at 10 GHz |
| Thickness ± tolerance | Impedance and mechanical stiffness | 0.127–6.0 mm, ±10 % class |
| Copper type / weight | Conductor loss and PIM | ED standard, RTF on F4BME, 1/2–2 oz |
If a quotation sheet gives you Dk and Df without tolerances and without a test frequency, it is not a datasheet yet.
2. Dk: the Number, Its Tolerance, and What the Two Together Cost
The F4BM ladder is a set of fixed Dk points — that is its selling point and its limitation. Reading a sheet, check that the grade code matches the Dk on the page (220 means 2.20) and that the tolerance is quoted for that grade, not borrowed from another:
| Grade | Dk | Tolerance | Typical use |
|---|---|---|---|
| F4BM217 | 2.17 | ± 0.04 | Minimum-loss feeds |
| F4BM220 | 2.20 | The workhorse grade | |
| F4BM255 | 2.55 | Smaller antennas, moderate loss | |
| F4BM294 | 2.94 | Compact passive networks | |
| F4BM300 | 3.00 | Shrinkage over loss |
On F4BM220 a ±0.04 tolerance is ±1.8 % of Dk, which moves a 50 Ω line by roughly ±0.9 %. That is the number to put into the tolerance stack, not the nominal. A sheet quoting ±0.02 on a 2.20 grade is usually quoting a 5880-class figure by mistake — ask for the maker’s page.
3. Df: Always Read the Frequency Next to It
Df without a test frequency is meaningless, because dielectric loss rises with frequency. The F4BM range at 10 GHz is 0.0010 on the 2.20 grade rising to 0.0018 on the 3.00 grade: the loss you pay is part of the grade choice, not a fixed property of “F4B”.
Two reading traps. First, a single number quoted for the whole family — 0.0013 appears in many listings because it is the F4BM255 value, not a general one. Second, a Df quoted at 1 MHz from a different measurement class; PTFE values are stable, but the document should still say which method and which frequency. If the sheet says “<0.002 @10GHz”, treat it as a ceiling and ask for the measured value on your grade.
4. Thickness: the Ladder and Its ±10 %
Thickness is the variable that quietly moves every impedance in a stackup, so the tolerance matters as much as the nominal. The standard ladder plus the ±10 % class band:
| Thickness | ±10 % band | Typical role |
|---|---|---|
| 0.127 mm | 0.114–0.140 | mmWave cores; thin, etch-sensitive |
| 0.254 mm | 0.229–0.279 | Reference RF core |
| 0.508 mm | 0.457–0.559 | Power feeds, low-band antennas |
| 1.000 mm | 0.900–1.100 | Structural RF boards |
| 1.600 mm | 1.440–1.760 | Standard thickness; aspect-ratio ceiling |
A ±10 % thickness band is ±6 % impedance on its own — larger than the Dk tolerance contribution. This is why the thickness column deserves the same attention as the dielectric constant, and why thin cores are specified with a tighter class. The mapping from thickness to line width is tabulated in the F4BM220 introduction; the tolerance-stack logic is in the impedance control guide.
5. Copper Type: the Field That Changes PIM, Not Just Loss
Two F4B grades share electrical parameters and differ only in foil: F4BM uses standard ED copper, F4BME uses reversed-treated foil (RTF). RTF gives a smoother copper-resin interface, which lowers insertion loss slightly and improves PIM — the reason base-station antenna work asks for it. A datasheet that lists “ED copper” only is telling you the grade is F4BM, not F4BME.
Copper weight belongs in the same row: 1/2 oz for fine-line mmWave, 1 oz as the default, 2 oz only where current demands it — heavier copper and sub-0.15 mm lines do not coexist comfortably. The foil taxonomy is in the copper foil guide.
6. Sheet Size: Read the Interlock, Not Just the List
Standard panels run 460×610 up to 1000×1200 mm, with several common sizes in between and custom cuts available. The line that matters is the restriction at the edges of the thickness range:
| Condition | Panel size allowed | Why |
|---|---|---|
| 0.2–4.0 mm | Full standard range, e.g. 460×610 to 1000×1200 | Handling and flatness are manageable |
| ≥ 4.0 mm or ≤ 0.2 mm | Max 500×610 | Thick panels sag, thin panels crease |
| Custom shapes | 250×300 up to 1000×1500 on request | Yield loss is priced in |
Panel size drives material utilization, and utilization is a bigger line in the quote than most designers expect: a layout that fits 460×610 efficiently can beat a nominally cheaper grade that wastes 30 % of the sheet. Cutting practice — oversize blank, relaxation, no water cooling — is covered in the substrate cutting guide.
7. The Mechanical Row: Peel, Solder, Warpage
These three numbers are incoming-inspection gates rather than design inputs, but a sheet without them is incomplete:
| Property | Value to look for | What it protects against |
|---|---|---|
| Peel strength | ≥ 18 N/cm (F4BM220 class) | Copper lifting during assembly or rework |
| Solder endurance | 260 °C / 20 s, no blister | Delamination in reflow |
| Warpage | Assembly placement error | |
| Water absorption | Dk shift in humid service |
Note the water absorption value: 0.02 % circulates on dealer sites, but the documented figure for this class is ≤0.08 %. Both are low; only one is defensible in an audit.
8. What the Sheet Does Not Tell You
Four things decide whether a design works and are absent from most F4B sheets:
TCDk. On F4BM220 it is −142 ppm/°C — about 1.4 % of Dk over 100 K. If your drawing has a phase tolerance, this number, not Df, sets the floor. Z-CTE. 240 ppm/°C caps aspect ratio near 6:1 on PTFE. Desmear chemistry. Plasma or sodium naphthalenide, not permanganate — a process line without either cannot build the board regardless of the datasheet. Etch sensitivity. ±25 µm on a 0.71 mm line is ±3 % impedance; on a 0.36 mm line it is ±6 %.
Ask for those four in writing. A supplier who cannot answer them has not built the material — the process detail behind each is in the F4BM220 fabrication page. The grade list itself, with the F4BME and F4BTM branches, is in the complete model list.
9. Four Values That Signal a Wrong Document
| What the sheet says | Why it is wrong | What to ask instead |
|---|---|---|
| Dk 2.20 ± 0.02 | That is the 5880 tolerance, not F4BM220 (±0.04) | Maker page for the exact grade code |
| Df 0.0009–0.0030 | Range spans an order of magnitude across the whole PTFE market, not one ladder (0.0010–0.0018) | Df for your grade at a stated frequency |
| Df 0.0017 @10GHz for “F4B” | 0.0017 is the F4BM294 value | Which grade code does this number belong to? |
| Dk 2.2–2.65 | Understates the ladder: F4BM reaches 3.00 and F4BTM 3.5 | Full grade table with tolerances |
None of these errors is exotic — they are what happens when a specification is copied from a Rogers datasheet onto a domestic product page. Reading the four lines with their qualifiers catches all of them.
Frequently Asked Questions
What Dk and Df should an F4B sheet quote?
Why does my quotation say Dk 2.20 ± 0.02?
Can I order a 0.127 mm sheet in 1000×1200 mm?
What is the difference between F4BM and F4BME on a datasheet?
Where do I find TCDk and Z-CTE if the sheet omits them?
Is a thinner core always better for impedance control?
Send the Datasheet You Were Quoted
Send us your Gerber files and requirements for a manufacturability review and a tailored quotation.
sales1@xcepcb.com
+86 180 3341 4657